RC1xx/TR-RC1xx | |
| FAt | (Event) An over temperature error has occurred. |
| FAC | (Event) An over current error has occurred. |
| PO | (Error) The internal power dissipation is too high. Output turned off/ |
| OP | (Error) The output current to the light is too low or the requested output current requires too high a voltage. |
| SH | (Error) The output is short circuit or the output current is too high. |
| HI | (Error) The voltage required for the lighting has increased too much. Check for ageing of the light or a failed LED. |
| LO | (Error) The voltage required for the lighting has decreased too much. Check for ageing of the light or a failed LED. |
| FAC | (Fatal error) The unit is outputting more current than expected. |
| FAt | (Fatal error) The RC1xx is too hot. The unit has a thermal cut out which operates at approximately 65°C to 70°C depending on conditions. |
| FAS | (Error) Internal protection has activated to prevent too much heat in the output driver. |
| FAA | (Error) The light is not compatible with the controller. The TR-RC1xx does not drive the light and the web page reports ‘Triniti Chip device protection’. |
TR-CL180 | |
| FAt | (Event) An over temperature error has occurred. |
| FAt | (Fatal error) The TR-CL180 is too hot. The unit has a thermal cut out which operates at approximately 65°C to 70°C depending on conditions. |
RT200 | |
| FAt | (Event) An over temperature error has occurred. |
| FAC | (Event) An over current error has occurred. |
| PO | Internal power dissipation is too high. Output turned off. Or internal protection has prevented SafePower voltage going too high. |
| OP | Output current to lighting is too low or the requested output current requires too high a voltage. |
| SH | The output is short circuit, or the output current is too high, or the voltage required for the lighting has decreased too much. Check for ageing of the lighting or a failed LED. |
| HI | The voltage required for the lighting has increased too much. Check for ageing of the lighting or a failed LED. |
| LO | The voltage required for the lighting has decreased too much. Check for ageing of the lighting or a failed LED. |
TR-HT2xx | |
 | "Error 44 High Temp" - (Event) An over temperature error has occurred. |
 | "Error 41 High Cur" - (Event) An over current error has occurred. |
 | "Error 22 Trin Manu" - (Error) The light is not compatible with the controller. The TR-HT2xx does not drive the light and the web page reports ‘Triniti Chip device protection’ |
 | "Error 34 High Pow" - (Error) The internal power dissipation is too high. Output is turned off. Or the voltage required for the lighting has increased too much. Check for ageing of the light or a failed LED. |
 | "Error 35 Open Cir" - (Error) The output current to the light is too low. |
 | "Error 36 Short Cir" - (Error) The output is short circuit. |
 | "Error 37 High Vol" - (Error) The voltage required for the lighting has increased too much. Check for ageing of the light or a failed LED. |
 | "Error 38 Low Vol" - (Error) The voltage required for the lighting has decreased too much. Check for ageing of the light or a failed LED. |
 | "Error 41 High Cur" - (Fatal error) The unit is outputting more current than was expected. |
 | "Error 42 High Cur" - (Error) The output current is too high. |
 | "Error 43 High Vol" - (Error) The requested output current requires too high a voltage. |
 | "Error 44 High Temp" - (Fatal error) The TR-HT is too hot. The unit has a thermal cut out which operates at approximately 65°C to 70°C depending on conditions. |
 | "Error 46 Light Pow" - (Error) The maximum average power output has been exceeded. Reduce the brightness in the configuration. |
 | "Error 47 Unstable" - (Error) The controller was unable to reach a stable output for this light. Try reducing the brightness in the configuration. |